    Î÷ÃÅ×Ó840CÊý¿ØÏµÍ³Î¬ÐÞ ÏÔʾ±¨¾¯´úÂë43ºÅÐÞÀí·½°¸

    ·¢²¼Õߣº±äƵÆ÷άÐÞ²¿    À´Ô´£ºÉϺ£Ñö¹âµç×Ó¹¤³Ì²¿     ·¢²¼Ê±¼ä£º2021-3-12

    Î÷ÃÅ×Ó840CÊý¿ØÏµÍ³Î¬ÐÞ ÏÔʾ±¨¾¯´úÂë43ºÅÐÞÀí·½°¸

       Î÷ÃÅ×Ó840CÊý¿ØÏµÍ³Î¬ÐÞÖÐÐÄ£º

    IEMENS
    Î÷ÃÅ×Ó810D/840DI/840CάÐÞÊý¿ØÏµÍ³Î¬ÐÞ
    SINUMRIK
    Î÷ÃÅ×Ó810D  Êý¿ØÏµÍ³Î¬ÐÞ
    Î÷ÃÅ×Ó840DI Êý¿ØÏµÍ³Î¬ÐÞ
    Î÷ÃÅ×Ó840D  Êý¿ØÏµÍ³Î¬ÐÞ
    Î÷ÃÅ×Ó840C  Êý¿ØÏµÍ³Î¬ÐÞ
    1- SIEMENSÎ÷ÃÅ×Ó 810D¡¢840D¡¢840CµÈÊý¿Ø¡¢Êý¿ØÏµÍ³¡¢¿ØÖư忨¡¢Ä£¿éÏúÊÛάÐÞ£»
    2- SIEMENS Î÷ÃÅ×ÓËÅ·þÇý¶¯¡¢ËÅ·þµçԴάÐÞ£¬6SN¡¢610¡¢611ϵÁÐËÅ·þÇý¶¯µçÔ´Ä£¿é¼°Çý¶¯Æ÷άÐÞ


      Î÷ÃÅ×Ó840Cϵͳ»Ö¸´²ÎÊýÈçÏ£º
    1¡£SET THE CSB SWITCH TO POSITION 4¡£1£¬°ÑCSB°åÉϵĿª¹Ø¿ªµ½4ÉÏ¡£
    2¡£POWER ON THE MACHINE AND CONTROL£¨MAIN LINE DISCONNECT£©2£¬»ú´²ÉϵçºÍ¿ØÖÆ
    3¡£PRESS-MENU SELECT 3£¬°´ÏÂ-²Ëµ¥Ñ¡Ôñ
    4¡£SK-DIAGNOSIS 4£¬Èí¼ü-Õï¶Ï5£¬SK-START UP 5£¬Èí¼ü-Æô¶¯
    6£¬SK-MACHINE DATA 6£¬Èí¼ü-»ú´²Êý¾Ý
    7£¬SK-FILE FUNCTIONS 7£¬Èí¼ü-Îļþº¯Êý
    8¡£USE THE NORTHWEST KEY TO ACTIVATE THE UPPER WINDOW¡£8¡£Ê¹ÓÃбÉÏ·½¼üµ½ÉÏÒ»¸öͼ¿ò
    9¡£HIGHLIGHT STANDD-T£¨FOR TURNING MACHIES£©OR STANDD-M£¨FOR MILLING OR MULTI-AXIS MACHIES£©9¡£±ê¼ÇSTANDD-T£¨ÔÚ»ú´²×ªÍä´¦)»ò±ê¼ÇSTANDD-M 
    10£¬SK-LOAD FROM DISK  10£¬Èí¼ü-ÉÏÔØÀ´×Ô´ÅÅÌ
    11£¬SK-LOAD START 11£¬Èí¼ü-ÉÏÔØÆô¶¯
    12£¬A MESSAGE WILL APPER¡°TRANSFER FROM PC TO NC IN PROGRESS¡±£»

    12£¬»áÏÔʾÐÅÏ¢¡°×ªÒÆÀ´×ÔPCµ½NC½øÕ¹¡±
    13£¬HIGHLIGHT STANDARD 13£¬±ê¼Ç±ê×¼ 
    14£¬SK-LOAD FROM DISK 14,Èí¼ü-ÉÏÔØÀ´×Ô´ÅÅÌ 
    15£¬SK-LOAD START 15£¬Èí¼ü-ÉÏÔØ¼¤»î 
    16£¬A MESSAGE WILL APPER¡°TRNSFER FROM PC TO NC IN PROGRE¡± 16£¬»áÏÔʾÐÅÏ¢×ªÒÆÀ´×ÔPCµ½NC½øÕ¹ 
    17£¬SUB UP ONE LEVEL 17£¬·µ»ØÉϼ¶ 
    18¡£SK-NC MD 18£¬Èí¼ü-NC Êý¾Ý  
    19¡£SK-FILE FUNCTIONS 19£¬Èí¼ü-Îļþº¯Êý 
    20¡£ENSURE THAT THE BOTTOM WINDOW IS ACTIVE£¨YELLOW OR GREEN BORDER£© 20¡£È·ÈÏÄǸöµ×²¿´°¿ÚµÄÑÕÉ«£¨»ÆÉ«»òÂÌÉ«µÄ±ß£© 
    21£¬SK-LOAD FROM DISK 21£¬Èí¼ü-ÉÏÔØÀ´×Ô´ÅÅÌ 
    22£¬SK-LOAD START  22£¬Èí¼ü-ÉÏÔØ¼¤»î 
    23£¬SUB UP TO 2 LEVELS 23£¬·µ»Ø 24£¬SK-PLC MD 
    24£¬Èí¼ü-PLCÊý¾Ý 25£¬SK-FILE FUNCTIONS 
    25£¬Èí¼ü-Îļþº¯Êý 
    26£¬ENSURE THAT THE BOTTOM WINDOW IS ACTIVE£¨YELLOW OY GREEN BORDER£© 26£¬È·ÈÏÄǸöµ×²¿´°¿ÚµÄÑÕÉ«£¨»ÆÉ«»òÂÌÉ«µÄ±ß£© 
    27£¬SK-LOAD FROM DISK 27£¬Èí¼ü-ÉÏÔØÀ´×Ô´ÅÅÌ 
    28£¬SK-LOAD START 28£¬Èí¼ü-ÉÏÔØ¿ªÊ¼ 
    29£¬MESSAGE¡°TRANSER FROM PC TO NC IN PROGRESS¡± 29£¬ÐÅÏ¢¡°Òƶ¯À´×ÔPCµ½NC½øÕ¹¡± 
    30£¬BEFORE THE TEA3 FILE IS LOADED THE DRIVE MEMORY AND PLC MEMORY HAVE TO BE RESET £¬THE PLC MUST BE IN RUN MODE£¨TWO GREEN LED'S£© 
    30¡£ÔÚTEA3ÎļþÉÏÔØÖ®Ç°£¬Çý¶¯Ä£¿éºÍPLCÄ£¿é±ØÐë±»¸´Î»£¬PLC±ØÐë±»¼¤»î£¨Á½¸öÂ̵ÆÁÁ 
    31£¬POWER OFF THE MACHINE AND CONTROL£¨MAIN LINE DISCONNECT£© 31£¬¸ø»ú´²¶Ïµç 
    32£¬SET THE CSB SWITCH TO POSITION 0 32£¬½«CSB°åÉϵĿª¹Ø²¦µ½0 
    33£¬POWER ON THE MACHINE AND CONTROL£¨MAIN LINE DISCONNECT£© 33£¬»ú´²Éϵç 
    34£¬PRESS-MENU SELECT  34£¬°´Ï²˵¥Ñ¡Ôñ 
    35£¬SK-DIAGNOSIS 35£¬Èí¼ü-Õï¶Ï 
    36£¬SK-START UP  36£¬Èí¼ü-Æô¶¯ 
    37£¬SK-MACHINE DATA  SET PASSWORD£¬AS REQUIRED 37£¬Èí¼ü»ú´²Êý¾Ý£¬±à¼­ÃÜÂ룬ÕâÊDZØÐëµÄ¡£1111 
    38£¬SK-PLC MD 38£¬Èí¼ü-PLCÊý¾Ý 
    39£¬SK-FILE FUNCTIONS 39£¬Èí¼ü-Îļþº¯Êý 
    40£¬ENSURE THAT THE BOTTOM WINDOE IS ACTIVE£¨YELLOW OR GREEN BORDER£© 40£¬È·ÈÏÄǸöµ×²¿µÄ¿òµÄÑÕÉ«£¨»ÆÉ«»òÂÌÉ«µÄ±ß£©
    41£¬SK-LOAD FROM DISK  41£¬Èí¼ü¡ª¡ªÉÏÔØÀ´×Ô´ÅÅÌ 
    42£¬SK- LOAD START 42£¬Èí¼ü-ÉÏÔØ¿ªÊ¼ 
    43£¬MESSAGE¡°TRANSFER FROM PC TO NC IN PROGRESS¡± 43£¬ÐÅÏ¢¡°Òƶ¯À´×ÔPCµ½NC½øÕ¹¡± 
    44£¬SUB UP THREE LEVELS 44,·µ»ØÉϼ¶²Ëµ¥ 
    45£¬SK-GENERAL RESET MODE 45£¬Èí¼ü-×ÜÌ帴λģʽ 
    46£¬SK-END GEN RESET MODE 46£¬Èí¼ü¡ª½áÊø×ÜÌ帴λģʽ 
    47£¬PRESS MENU SELECT 47£¬°´Ï²˵¥Ñ¡Ôñ 
    48£¬SK-DIAGNOSIS 8£¬Èí¼ü-Õï¶Ï 
    49£¬SK-MACHINE DATA  49£¬Èí¼ü-»ú´²Êý¾Ý 
    50£¬SK-DRIVE MA 50£¬Èí¼ü-Çý¶¯Êý¾Ý 
    51£¬SK-FILE FUNCTIONS 51£¬Èí¼ü-Îļþº¯Êý 
    52£¬ENSURE THAT THE BOTTOM WONDOEN IS ACTIVE£¨YELLOW OR GREEN BORDER£© 52£¬È·ÈÏÄǸöµ×²¿¿òµÄÑÕÉ«£¨»ÆÉ«»òÂÌÉ«µÄ±ß£© 
    53£¬SK-LOAD FROM DISK  53£¬Èí¼ü-ÉÏÔØÀ´×Ô´ÅÅÌ 
    54£¬SK-LOAD START 54£¬Èí¼ü-ÉÏÔØ¿ªÊ¼ 
    55£¬SUB UP ONE LEVEL 55£¬·µ»Ø 
    56£¬VERTICAL SK-ACCEPT CONF+NCKPO 56£¬´¹Ö±Èí¼ü-ACCEPT CONF+NCKPO£© 
    57£¬THIS WILL GET THE MODULE DATA FOR THE FILE YOU BACKED UP 57£¬Õ⽫ҪµÃµ½Ä㱸·ÝÉϵĵ¥ÔªÊý¾ÝÎļþ 
    58£¬THE SCREEN WILL GO TO THE MACHINE DISPLAY BECAUSE OF THE NCK POWER ON 58£¬ÒòΪNCKµçÔ´¿ªËùÒÔÕâ¸ö´°¿Ú½«ÒªÈ¥»ú´²ÏÔʾ 
    59£¬PRESS THE MENU SELECT KEY TWICE TO GO BACK TO THE DRIVE CONFIGURATION SCREEN 59£¬°´Ñ¹Á½´Î²Ëµ¥Ñ¡Ôñ¼üÈ¥Çý¶¯ÅäÖýçÃæ                                                           
    60£¬SK-FILE FUNCTIONS 60£¬Èí¼ü-Îļþº¯Êý 
    61£¬SK-LOAD FROM DISK 61£¬Èí¼ü-ÉÏÔØÀ´×Ô´ÅÅÌ  
    62£¬AT THE BOTTOM RIGHT OF THE SCREEN £¬NOTE THE ¡°AREA¡±FIELD DDISPOLAYS ¡°CONFIG¡±¡£YOU MUST USE THE SELECT KEY TO CHANGE IT TO ¡°DRIVES¡± 62£¬Ôڵײ¿ºÏ·¨´°¿ÚÄÚ£¬½«CONFIG¸ÄΪDRIVES 
    63£¬SK-LOAD START¡£THIS MAY TAKE A COUPLE OF MINUTES TWENTY MINUTES WOULD BE VERY EXCESSIVE 63£¬Èí¼ü£¬ÉÏÔØ¿ªÊ¼¡£ÕâÐèÒª×î¶à20·ÖÖÓµÄʱ¼ä(ÕâÀï×°ÔØµÄΪԭʼ±¸·ÝÎļþ£¬ÐèÒªºË¶ÔÇý¶¯Êý¾Ý£© 
    64£¬AFTER IT COMPLETES THE TRANSFER£¬SUB UP 1LEVEL 64£¬ÔÚÒÆ¶¯½øÕ¹ºó£¬·µ»Ø 
    65£¬VERTICAL SK-ACCEPT ALL+NCKPO 65£¬×ÝÏòÈí¼ü-ACCEPT ALL+NCKPO 
    66£¬THIS WILL GET THE MOTOR DATA£¬COMBINE IT IN WITH THE CONFGURATION DATA£¬MAKE A BOOT FILE AND LOAD IT IN THE DRIVE SYSTEM 66£¬Õ⽫µÃµ½»ú´²Êý¾Ý£¬ÁªºÏ»ú´²ÅäÖÃÊý¾Ý 
    67£¬THE RED LED'S ON THE DRIVES WILL EXTINGUISH 67£¬Çý¶¯°àÉϵĺìɫָʾµÆ½«ÒªÏ¨Ãð£¬ÏµÍ³°åÉϵÄÁ½¸öÂÌÉ«µÆÁÁ¡£ 



    ×ªÔØÇë×¢Ã÷³ö´¦£ºÉϺ£Ñö¹âµç×ӿƼ¼×¨ÒµËÅ·þÇý¶¯Æ÷άÐÞ,ËÅ·þµç»úάÐÞ
    ±¾ÎÄÁ´½Ó£º/fuwu/Services_Show4338.htm
    ËÅ·þÇý¶¯Æ÷άÐÞ ËÅ·þµç»úάÐÞ  ´¥ÃþÆÁάÐÞ   ±äƵÆ÷άÐÞ


    ÁªÏµ·½Ê½£º

    µç»°£º021-50157782
    ÊÖ»ú£º13817011982 ΢ÐÅͬºÅ
    ÓÊÏ䣺shygdzi@163.com
    ÁªÏµÈË£ºÕʤ
    꿅᣼
    ¡¾ ÎÒÃÇÈ·±£Ð޺òâÊԺøø¿Í»§£¡£¡£¡£¡¡¿

    ÉÏһƪ£º±´¼ÓÀ³ÏµÍ³ÆÁÏÔʾE4άÐÞ ±´¼ÓÀ³Êý¿ØÏµÍ³±¨¾¯´úÂëÔõô°ì£¿
    ÏÂһƪ£ºfagorµç»ú³£¼û¹ÊÕÏÅŲ鼰άÐÞ

    ×îÐÂÏà¹ØÄÚÈÝÍÆ¼ö£º
     

    ¡¾ÍøÕ¾µØÍ¼¡¿¡¾sitemap¡¿